Accessibility options
Useable Capacity, C-Rate and Efficiency
Current, voltage and useable charge
Show the full working
What to try
- Choose 3C and press Discharge to cut-off. How much charge is left in the cell?
- Now press Carry on at 0.5C. Does more charge come out? Was it lost, or stranded?
- Press Charge back up. The shaded loop is the energy lost. Is it larger at 3C or at 0.5C?
- Raise the cut-off to 3.4 V. What happens to the useable capacity?
What's next
Inside the Li-ion cell. The next lesson follows the lithium itself between the graphite and the cobalt oxide layers, and the cell voltage as the state of charge changes.
Remember: useable capacity and efficiency
- I = C-rate × capacity: a 3.35 Ah cell at 2C gives 6.70 A and empties in about 1/2 h.
- On discharge V = OCV − iR; on charge V = OCV + iR. A larger current reaches the cut-off sooner, leaving charge stranded in the cell: a smaller current can still take it out.
- Coulombic efficiency = charge out / charge in. Voltage efficiency = mean discharge voltage / mean charge voltage. Energy efficiency = coulombic × voltage: on the graph, the loop between the charge and discharge curves is the energy lost.
- A lower cut-off gives more charge per cycle; a higher one is gentler on the electrodes, so the cell lasts more cycles.
Representative 18650 lithium-ion cell: graphite (C6) negative and lithium cobalt oxide (LiCoO2) positive, 3.35 Ah, 4.20 V full and 3.00 V empty at open circuit, internal resistance 0.050 Ω. The open-circuit curve is representative; the coulombic efficiency is taken as 99.5 %. On charge the voltage rises to 4.20 V, which the charger then holds (constant voltage) while the current falls; here that step is drawn at the same rate for simplicity.