Back to CHM3005 Lessons

Useable Capacity, C-Rate and Efficiency

The C-rate sets the current: at 1C a full cell empties in an hour. A faster discharge means a larger iR drop, so the voltage reaches the cut-off voltage sooner and charge is left in the cell. A full charge and discharge also loses energy: the voltage, coulombic and energy efficiencies say how much.

1.0C · 3.35 A
0.050 Ω
3.00 V
What to try
  • Choose 3C and press Discharge to cut-off. How much charge is left in the cell?
  • Now press Carry on at 0.5C. Does more charge come out? Was it lost, or stranded?
  • Press Charge back up. The shaded loop is the energy lost. Is it larger at 3C or at 0.5C?
  • Raise the cut-off to 3.4 V. What happens to the useable capacity?
What's next

Inside the Li-ion cell. The next lesson follows the lithium itself between the graphite and the cobalt oxide layers, and the cell voltage as the state of charge changes.

Remember: useable capacity and efficiency
  • I = C-rate × capacity: a 3.35 Ah cell at 2C gives 6.70 A and empties in about 1/2 h.
  • On discharge V = OCV − iR; on charge V = OCV + iR. A larger current reaches the cut-off sooner, leaving charge stranded in the cell: a smaller current can still take it out.
  • Coulombic efficiency = charge out / charge in. Voltage efficiency = mean discharge voltage / mean charge voltage. Energy efficiency = coulombic × voltage: on the graph, the loop between the charge and discharge curves is the energy lost.
  • A lower cut-off gives more charge per cycle; a higher one is gentler on the electrodes, so the cell lasts more cycles.

Representative 18650 lithium-ion cell: graphite (C6) negative and lithium cobalt oxide (LiCoO2) positive, 3.35 Ah, 4.20 V full and 3.00 V empty at open circuit, internal resistance 0.050 Ω. The open-circuit curve is representative; the coulombic efficiency is taken as 99.5 %. On charge the voltage rises to 4.20 V, which the charger then holds (constant voltage) while the current falls; here that step is drawn at the same rate for simplicity.